HBOT YF-1001
YF-1001 Home Hyperbaric Chamber: Lying Layout and Installation
What pressure settings are available?
Pressure settings include six levels: 1.1, 1.3, 1.5, 1.6, 1.8 and 2.0 ATA; optional configurations can reach 2.5 ATA.
High-pressure protection
a password is required when the set pressure is ≥1.6 ATA to prevent accidental operation
Water-cooled air conditioning
the external HF-10 chiller is 220 V, 50 Hz and ≤1000 W; in-cabin equipment uses low-voltage 12 V or 24 V power.
Two-way internal/external intercom
built-in in-chamber and external intercom units provide real-time two-way communication.
Ventilation and pressure regulation
the forced-air circulation system brings air in and exhausts it simultaneously to keep the chamber air fresh.
Customization
OEM/ODM support for chamber shell, floor, carpet, interior and seat colors
Product description

Layout and selection
Product type: Single-person reclining hard-shell hyperbaric chamber
YF-1001 is a reclining model with a chamber height of 1150 mm (45.3 in).
The cabin has a transparent door, viewing windows and two-way communication. Compare the cabin dimensions, oxygen flow and pressure settings with the room and equipment space planned for installation.
- Model
- YF-1001
- Capacity
- 1 person
Home Hyperbaric Oxygen Chamber Technical Specifications
Technical parameters
- Model
- YF-1001
- Capacity
- 1 person
- Dimensions
- 2200 × 1015 × 1150 mm (86.6 × 40.0 × 45.3 in)
- Oxygen flow
- 10 L/min
- Oxygen concentration
- 93% +/- 3%
- Auxiliary equipment rated supply
- 220 V, 50 Hz
- What pressure settings are available?
- Pressure settings include six levels: 1.1, 1.3, 1.5, 1.6, 1.8 and 2.0 ATA; optional configurations can reach 2.5 ATA.

Product advantages

Pressure and time control
Pressure settings include six levels: 1.1, 1.3, 1.5, 1.6, 1.8 and 2.0 ATA, with an optional configuration reaching up to 2.5 ATA. The settings accommodate different pressure requirements. Session times of 20, 40, 60, 80 and 120 minutes are supported, with internal and external interfaces for convenient setup and monitoring.
The control layout brings session settings and monitoring into the same operating area. Select the pressure and duration for the confirmed configuration, and review the internal and external interfaces during setup. This helps the operator check settings and follow the session without relying on a single viewing position.

Customizable
The chamber exterior color, interior colors and other finishes can be customized.
Choose a coordinated exterior and interior palette to suit the room, whether the chamber is placed in a private residence or a dedicated business space. Review the colours alongside the door, viewing windows and upholstery shown for this model. Confirm the final finish selection before production so the cabin arrives with the agreed appearance.

Rounded chamber structure
A circular or elliptical shell distributes pressure more evenly, reducing stress concentration and supporting long-term use.
The curved shell forms the main cabin around the selected seating or reclining layout. When planning the room, review both the external dimensions and the usable interior space, with enough room around the door for entry, observation and routine equipment access.

Single-person reclining hyperbaric oxygen chamber
Elliptical chamber with spacious interior lying space; transparent door and viewing windows, diamond-stitched soft padding, and an integrated monitoring and control panel support comfortable rest and real-time observation of the chamber interior during operation.
The reclining arrangement is designed around one occupant, with the door and windows keeping the cabin interior visible from outside. Consider the reclining position, the access side and the external equipment together when planning the room. The 1150 mm cabin height helps define the available interior profile; use the full dimension drawing to check the installation space.

Oxygen delivery system
Standard nasal oxygen delivery with an oxygen flow of 10 L/min. A mask option can be confirmed for the project.

YF-10 oxygen generator and control system
The YF-10 delivers 10 L/min of oxygen. It measures 640 × 460 × 1100 mm, weighs 90 kg and runs on 220 V / 50 Hz with power consumption up to 1200 W. The coated alloy unit includes a flow meter, power cord and connecting air tube.
Project support
OxySail is a factory-direct hyperbaric oxygen chamber manufacturer in China, manufacturing and exporting since 2014 to over 70 countries. We offer OEM/ODM services and exclusive product development for distributors and brands, customizing exterior designs, interiors, seating and functions to suit each market. Our hard shell hyperbaric chamber range includes YF-1003, YF-1004 and two-person YF-2003 models for homes, clinics and wellness businesses. We provide factory-direct pricing, warranty support, and remote installation and operation guidance.

Project support
- Manufacturing and export since 2014
- Products supplied to more than 70 countries
- OEM/ODM and dedicated product development
- Factory-direct pricing and warranty support
- Remote installation and operating guidance
Product videos
See the YF-1001 exterior, door opening, cabin layout and dimensions, with a closer look at access conditions.
YF-1001 product showcase
Exterior, door opening and cabin layout.
Watch on YouTube ↗Application
Explore YF-1001 in hospitality, fitness, residential and wellness settings.






Materials and safety design
Materials and chamber structure
- Door 25 mm PC | Panel material: PC board
- A reinforced door panel supports a stable seal and repeated daily access.
- Window 25 mm PC | Panel material: PC board
- The viewing panel balances visibility with the protection expected from the cabin enclosure.
- Door frame and interior structure Carbon steel
- Carbon steel is used for the door frame and interior structural components; it is not the pressure-bearing shell.
- Pressure-bearing shell 5 mm steel plate
- The chamber pressure shell is made from 5 mm steel plate.
Pressure monitoring
- Negative pressure gauge -100 to 0 kPa
- Identifies negative-pressure fault risk and alerts the operator to an abnormal state.
- Positive pressure gauge 0 to 250 kPa
- Monitors the chamber working pressure and supports the controlled pressurization and depressurization sequence.
Controls and equipment
Operating screens and two-way communication
- Inner screen
- The cabin display presents the key operating information inside the chamber.
- Outer screen
- The external panel keeps control information visible to the operator at the workstation.
- Inner call
- The cabin handset provides a direct voice channel for the occupant.
- Outer call
- The external handset lets the operator respond clearly without opening the chamber.
YF-1001 equipment and options
- Oxygen control system
- YF-10
- Oxygen flow
- 10 L/min
Seating or lying components depend on the selected model. Confirm the delivered equipment list for the project.
Exterior colors can be discussed by project. Confirm seating and oxygen-system options against the selected model.
Compare interior components and oxygen-system flow across the model range.
Details, customization and purchasing
Before purchasing
- Site dimensions and room layout
- Doorways, lifts and access route
- Power supply and equipment positioning
- Installation, commissioning and training
- Maintenance, consumables and after-sales response
Customization options
- Colour
- Bright white, matte black, gold silver, blue, metallic grey and more
- Seating and interior
- Materials, colours and space configuration
- Chamber and functions
- Exterior, interior, seating and functions
- Project delivery
- Production, assembly, packing, transport and installation
Contact Us