YF-1002
YF-1002 1.5–2.0 ATA Seated Hard-Shell Hyperbaric Chamber
Pressure settings
YF-1002 offers selectable settings up to 2.0 ATA.
Elliptical/round chamber design
evenly distributes force and resists deformation under sustained high pressure
High-pressure protection
a password is required when the set pressure is ≥1.6 ATA to prevent accidental operation
Water-cooled air conditioning
the external HF-10 chiller is 220 V, 50 Hz and ≤1000 W; in-cabin equipment uses low-voltage 12 V or 24 V power.
Two-way internal/external intercom
in-chamber and external communication units
Ventilation and pressure regulation
the forced-air circulation system brings air in and exhausts it simultaneously to keep the chamber air fresh.
Customization
OEM/ODM support for chamber shell, floor, carpet, interior and seat colors
Product description

Layout and selection
Product type: Single-person seated hard-shell hyperbaric chamber
The YF-1002 is a single-person seated hard-shell chamber measuring 1750 × 860/1025 × 1870 mm. Choose the 860 mm or 1,025 mm width for the room and access route, then select the YF-10 or YF-20 oxygen control system for the project.
Compare the cabin dimensions, seating or reclining layout, oxygen flow and pressure settings with your room plan. Allow space for the door opening, external equipment and routine access before confirming the installation position.
- Model
- YF-1002
- Capacity
- 1 person
1.5 ATA Hyperbaric Chamber Technical Parameters
Technical parameters
- Model
- YF-1002
- Capacity
- 1 person
- Dimensions
- 1750 × 860/1025 × 1870 mm (68.9 × 33.9/40.4 × 73.6 in)
- Oxygen flow
- 10/20 L/min
- Oxygen concentration
- 93% +/- 3%
- Auxiliary equipment rated supply
- 220 V, 50 Hz
- What pressure settings are available?
- Pressure settings include six levels: 1.1, 1.3, 1.5, 1.6, 1.8 and 2.0 ATA; optional configurations can reach 2.5 ATA.

Product advantages

Observation window design
Observation windows provide a view into the cabin for easier observation and communication.
Consider the window positions together with the door opening and the surrounding room layout. Keep the observation side accessible so an attendant can see the occupant and communicate easily. Review the sight lines from outside the chamber before deciding where the cabin and external equipment will stand.

Pressure and time control
YF-1002 provides selectable pressure settings up to 2.0 ATA, with controls for pressure and session time.
The control layout brings session settings and monitoring into the same operating area. Select the pressure and duration for the confirmed configuration, and review the internal and external interfaces during setup. This helps the operator check settings and follow the session without relying on a single viewing position.

Core materials and safety
Pressure-vessel-grade plate, high-performance PC doors and windows, eco-friendly automotive-grade interior materials and aluminium flooring support a safe, durable cabin.
Review the shell, transparent components, interior surfaces and flooring together when choosing the final configuration. Colours and finishes should work with the room and the intended cabin layout. Confirm the selected materials and equipment list before production so the delivered configuration matches the project.

Rounded chamber structure
A circular or elliptical shell distributes pressure more evenly, reducing stress concentration and supporting long-term use.
The curved shell forms the main cabin around the selected seating or reclining layout. When planning the room, review both the external dimensions and the usable interior space, with enough room around the door for entry, observation and routine equipment access.
Project support
OxySail is a factory-direct hyperbaric oxygen chamber manufacturer in China, manufacturing and exporting since 2014 to over 70 countries. We offer OEM/ODM services and exclusive product development for distributors and brands, customizing exterior designs, interiors, seating and functions to suit each market. Our hard shell hyperbaric chamber range includes YF-1003, YF-1004 and two-person YF-2003 models for homes, clinics and wellness businesses. We provide factory-direct pricing, warranty support, and remote installation and operation guidance.

Project support
- Manufacturing and export since 2014
- Products supplied to more than 70 countries
- OEM/ODM and dedicated product development
- Factory-direct pricing and warranty support
- Remote installation and operating guidance
Product videos
See the YF-1002 exterior, door opening, cabin layout and dimensions, with a closer look at access conditions.
YF-1002 product showcase
Exterior, door opening and cabin layout.
Watch on YouTube ↗Application
Explore YF-1002 in hospitality, fitness, residential and wellness settings.






Materials and safety design
Materials and chamber structure
- Door 25 mm PC | Panel material: PC board
- A reinforced door panel supports a stable seal and repeated daily access.
- Window 25 mm PC | Panel material: PC board
- The viewing panel balances visibility with the protection expected from the cabin enclosure.
- Door frame and interior structure Carbon steel
- Carbon steel is used for the door frame and interior structural components; it is not the pressure-bearing shell.
- Pressure-bearing shell 5 mm steel plate
- The chamber pressure shell is made from 5 mm steel plate.
Pressure monitoring
- Negative pressure gauge -100 to 0 kPa
- Identifies negative-pressure fault risk and alerts the operator to an abnormal state.
- Positive pressure gauge 0 to 250 kPa
- Monitors the chamber working pressure and supports the controlled pressurization and depressurization sequence.
Controls and equipment
Operating screens and two-way communication
- Inner screen
- The cabin display presents the key operating information inside the chamber.
- Outer screen
- The external panel keeps control information visible to the operator at the workstation.
- Inner call
- The cabin handset provides a direct voice channel for the occupant.
- Outer call
- The external handset lets the operator respond clearly without opening the chamber.
YF-1002 equipment and options
- Oxygen control system
- YF-10 / YF-20
- Oxygen flow
- Configurable by project — contact sales for the final flow specification
Seating or lying components depend on the selected model. Confirm the delivered equipment list for the project.
Exterior colors can be discussed by project. Confirm seating and oxygen-system options against the selected model.
Compare interior components and oxygen-system flow across the model range.
Details, customization and purchasing
Before purchasing
- Site dimensions and room layout
- Doorways, lifts and access route
- Power supply and equipment positioning
- Installation, commissioning and training
- Maintenance, consumables and after-sales response
Customization options
- Colour
- Bright white, matte black, gold silver, blue, metallic grey and more
- Seating and interior
- Materials, colours and space configuration
- Chamber and functions
- Exterior, interior, seating and functions
- Project delivery
- Production, assembly, packing, transport and installation
Contact Us
Tell us about this product and your project. Our team will follow up with the information you provide.