HBOT YF-2003
YF-2003 Two-Person HBOT Hyperbaric Chamber | Parallel-Seating Commercial Hyperbaric Chamber
What pressure settings are available?
Pressure settings include six levels: 1.1, 1.3, 1.5, 1.6, 1.8 and 2.0 ATA; optional configurations can reach 2.5 ATA.
Elliptical/round chamber design
evenly distributes force and resists deformation under sustained high pressure
High-pressure protection
a password is required when the set pressure is ≥1.6 ATA to prevent accidental operation
Water-cooled air conditioning
the external HF-10 chiller is 220 V, 50 Hz and ≤1000 W; in-cabin equipment uses low-voltage 12 V or 24 V power.
Two-way internal/external intercom
in-chamber and external communication units
Ventilation and pressure regulation
the forced-air circulation system brings air in and exhausts it simultaneously to keep the chamber air fresh.
Customization
OEM/ODM support for chamber shell, floor, carpet, interior and seat colors
Product description

Layout and selection
Product type: Two-person seated hard-shell hyperbaric chamber
YF-2003 is a two person hyperbaric chamber with a shared seated layout. Its hard-shell cabin measures 2070 × 1675 × 1800 mm (81.5 × 65.9 × 70.9 in). Check the seating arrangement and delivery access before selecting this model.
Compare the cabin dimensions, seating or reclining layout, oxygen flow and pressure settings with your room plan. Allow space for the door opening, external equipment and routine access before confirming the installation position.
- Model
- YF-2003
- Capacity
- 2 people
Hyperbaric Pressure Chamber Technical Parameters
Technical parameters
- Model
- YF-2003
- Capacity
- 2 people
- Dimensions
- 2070 × 1675 × 1800 mm (81.5 × 65.9 × 70.9 in)
- Oxygen flow
- 20 L/min
- Oxygen concentration
- 93% +/- 3%
- Auxiliary equipment rated supply
- 220 V, 50 Hz
- What pressure settings are available?
- Pressure settings include six levels: 1.1, 1.3, 1.5, 1.6, 1.8 and 2.0 ATA; optional configurations can reach 2.5 ATA.

Product advantages

Rounded chamber structure
A circular or elliptical shell distributes pressure more evenly, reducing stress concentration and supporting long-term use.
The curved shell forms the main cabin around the selected seating or reclining layout. When planning the room, review both the external dimensions and the usable interior space, with enough room around the door for entry, observation and routine equipment access.

Flexible oxygen inhalation
Nasal and face-mask inhalation options let users choose a delivery method that matches their habits and session needs.
Confirm the chosen delivery method and the oxygen equipment supplied with the chamber as part of the same configuration. Review the connection route and the position of the external unit before installation, leaving practical access for setup and routine checks.

Eco interior and cabin details
Soft upholstery, inner lining, lighting and control panels are arranged for comfort and easy maintenance, with finishes coordinated to the project.
Look at the lining, lighting and control positions as one interior layout rather than separate finishes. Review how the occupant enters, settles into position and communicates during a session. Confirm the chosen colours and surface finishes together with the final seating arrangement.

Observation window design
Observation windows provide a view into the cabin for easier observation and communication.
Consider the window positions together with the door opening and the surrounding room layout. Keep the observation side accessible so an attendant can see the occupant and communicate easily. Review the sight lines from outside the chamber before deciding where the cabin and external equipment will stand.
Project support
OxySail is a factory-direct hyperbaric oxygen chamber manufacturer in China, manufacturing and exporting since 2014 to over 70 countries. We offer OEM/ODM services and exclusive product development for distributors and brands, customizing exterior designs, interiors, seating and functions to suit each market. Our hard shell hyperbaric chamber range includes YF-1003, YF-1004 and two-person YF-2003 models for homes, clinics and wellness businesses. We provide factory-direct pricing, warranty support, and remote installation and operation guidance.

Project support
- Manufacturing and export since 2014
- Products supplied to more than 70 countries
- OEM/ODM and dedicated product development
- Factory-direct pricing and warranty support
- Remote installation and operating guidance
Product videos
See the YF-2003 exterior, door opening, cabin layout and dimensions, with a closer look at access conditions.
YF-2003 product showcase
Exterior, door opening and cabin layout.
Watch on YouTube ↗Application
Explore YF-2003 in hospitality, fitness, residential and wellness settings.






Materials and safety design
Materials and chamber structure
- Door 25 mm PC | Panel material: PC board
- A reinforced door panel supports a stable seal and repeated daily access.
- Window 25 mm PC | Panel material: PC board
- The viewing panel balances visibility with the protection expected from the cabin enclosure.
- Door frame and interior structure Carbon steel
- Carbon steel is used for the door frame and interior structural components; it is not the pressure-bearing shell.
- Pressure-bearing shell 5 mm steel plate
- The chamber pressure shell is made from 5 mm steel plate.
Pressure monitoring
- Negative pressure gauge -100 to 0 kPa
- Identifies negative-pressure fault risk and alerts the operator to an abnormal state.
- Positive pressure gauge 0 to 250 kPa
- Monitors the chamber working pressure and supports the controlled pressurization and depressurization sequence.
Controls and equipment
Operating screens and two-way communication
- Inner screen
- The cabin display presents the key operating information inside the chamber.
- Outer screen
- The external panel keeps control information visible to the operator at the workstation.
- Inner call
- The cabin handset provides a direct voice channel for the occupant.
- Outer call
- The external handset lets the operator respond clearly without opening the chamber.
YF-2003 equipment and options
- Oxygen control system
- YF-20
- Oxygen flow
- Configurable by project — contact sales for the final flow specification
Seating or lying components depend on the selected model. Confirm the delivered equipment list for the project.
Exterior colors can be discussed by project. Confirm seating and oxygen-system options against the selected model.
Compare interior components and oxygen-system flow across the model range.
Details, customization and purchasing
Before purchasing
- Site dimensions and room layout
- Doorways, lifts and access route
- Power supply and equipment positioning
- Installation, commissioning and training
- Maintenance, consumables and after-sales response
Customization options
- Colour
- Bright white, matte black, gold silver, blue, metallic grey and more
- Seating and interior
- Materials, colours and space configuration
- Chamber and functions
- Exterior, interior, seating and functions
- Project delivery
- Production, assembly, packing, transport and installation
Contact Us
Tell us about this product and your project. Our team will follow up with the information you provide.